Rivacold Manuals & Downloads
Technical documents for Rivacold refrigeration units, free to download.
- BEST Easy Manuals
- Preset Temperatures
- Temperature Parameters
- Data Sheets
- Range and Replacement Guide
- Getting the Size Right
- Other Ranges
- Older Units
- Can't Find Your Manual?
What is Rivacold BEST Easy?
The Rivacold BEST Easy is an indoor, wall-mounted monoblock refrigeration unit for coldrooms. It's the lower-cost version of Rivacold's BEST range: the same refrigeration hardware, sizes and capacities, but without the extras such as Bluetooth, the Rivacold app and remote monitoring. If you just need a unit to keep a room cold and don't need to check it from your phone, BEST Easy does the same job for less.
What does BYWT mean?
- BY: BEST Easy (full BEST models start BE)
- W: wall-mounted
- T: through-wall, fitted through an opening in the coldroom wall. BYWS is the saddle-mount version, which sits over the top of the wall.
All BEST Easy units run on R290 propane, with a charge of 150g or less per circuit. They're the modern replacement for Rivacold's older FA and FT Blocksystem units.
Check the model number on your unit's rating plate before you download, as older Rivacold ranges use different controllers and documents.
BEST Easy Manuals
Installation, operation and maintenance for BEST Easy units.
Rivacold BEST Wall Unit Instruction Manual (BEST and BEST Easy)
Rivacold's instruction manual for its BEST wall-mounted units. Covers installation of saddle-mount and through-wall units, the keypad controller, parameters, maintenance and fault diagnosis.
Using it on a BEST Easy unit: the manual is written for the full BEST range, which uses the same hardware as BEST Easy, so the installation, keypad operation and maintenance sections should apply. Ignore the sections on the MY I.D. app, Bluetooth, remote monitoring and pressure probes, as BEST Easy doesn't have these. If anything doesn't match your unit, contact us before going further.
Download Manual (PDF)Preset Temperatures
Rivacold's BEST wall-unit instruction manual lists default cooling setpoints of 0°C for chiller (NT/medium-temperature) units and −20°C for freezer (LT/low-temperature) units.
These are controller defaults, not a recommended storage temperature for every application. The installer should check the actual setpoint during commissioning and adjust it to suit the products being stored. For BEST Easy units, confirm the setting on the supplied controller and follow the documentation supplied with the unit; do not assume it has remained at the default.
Source: Rivacold BEST wall-unit instruction manual, version 02 (2023), section 8.6.1, page 48. The cooling setpoint is the parameter labelled Set.
Changing the Temperature and Key Parameters
| Parameter | Purpose |
|---|---|
| Set / SEt | Target cooling temperature. Documented defaults: chiller 0°C; freezer −20°C. |
| diF | Cooling differential: the temperature difference controlling cycling. Documented default: 2 K (a 2°C difference). This is not the target temperature. |
| LSE / HSE | Lower and upper limits for adjusting Set. The controller configuration determines which settings are available. |
Changing the setpoint
For the BEST wall-unit keypad described in the manual:
- Hold the confirm/setpoint button for 3 seconds, then release it. The display alternates between SEt and the current setting.
- Press that button briefly to edit the setting.
- Use the up/down buttons to choose the required temperature.
- Press the confirm button briefly to save.
Check that the keypad matches the manual before following these steps. BEST Easy and older Blocksystem controllers may differ; use the supplied instructions or send us a controller photo and model number.
Change Set to suit the product; leave differential and installer settings unchanged unless your engineer advises otherwise. If the required value is unavailable, ask us to check the model and controller rather than widening its limits.
The BEST Easy manufacturer listing gives operating ranges of −5°C to +15°C for chillers and −25°C to −10°C for freezers. These are equipment ranges, not product-storage recommendations or confirmation of the limits programmed into your controller. Use the storage specification for your product, allow the room to stabilise and check the product temperature. A colder setting can also affect unit sizing.
References: BEST wall-unit manual: section 6.2.3 (page 24) and section 8.6.1 (page 48); BEST Easy operating ranges.
BEST Easy Data Sheets
One PDF per model, showing unit dimensions, wall cut-out size, capacity tables and electrical data. Check the model number on the rating plate and pick the matching sheet.
Chillers
- BYWT251MA05P115.0 m³ data sheet
- BYWT251MA10P118.3 m³ data sheet
- BYWT251MA20P1111.9 m³ data sheet
- BYWT301MA30P1118.4 m³ data sheet
- BYWT301MA40P1123.9 m³ data sheet
- BYWT302MA50P1131.9 m³ data sheet
- BYWT352MA60P1141.5 m³ data sheet
- BYWT352MA70P1145.6 m³ data sheet
- BYWT352MA80P1155.0 m³ data sheet
Freezers
- BYWT251LA10P114.9 m³ data sheet
- BYWT251LA20P117.5 m³ data sheet
- BYWT301LA30P119.1 m³ data sheet
- BYWT301LA40P1110.4 m³ data sheet
- BYWT302LA50P1118.2 m³ data sheet
- BYWT352LA60P1129.6 m³ data sheet
- BYWT352LA70P1134.4 m³ data sheet
BEST Easy Range and Replacement Guide
Model sizes and matching old FA and FT units to their BEST Easy replacement.
Rivacold BEST Easy R290 Overview and FA/FT Cross-Reference
An overview of the BEST Easy R290 range, with tables matching older FA and FT (R452A) models to their BEST Easy replacement.
Use this for: finding the BEST Easy replacement for an old FA or FT unit. The tables list the saddle-mount BYWS codes. The through-wall BYWT units we sell come in the same sizes, so just swap BYWS for BYWT: for example, BYWS301MA30P11 becomes BYWT301MA30P11.
Shop the range: BEST Easy chiller monoblocks and BEST Easy freezer monoblocks.
Download Cross-Reference (PDF)BEST Easy Chiller Range
| Model | Capacity | Room size | Replaces old FA/FT |
|---|---|---|---|
| BYWT251MA05P11 | 641 W | 5.0 m³ | FTM003 (821 W) |
| BYWT251MA10P11 | 949 W | 8.3 m³ | FTM006 (975 W), FTM007 (1146 W) |
| BYWT251MA20P11 | 1265 W | 11.9 m³ | FTM009 (1302 W), FTM012 (1420 W) |
| BYWT301MA30P11 | 1645 W | 18.4 m³ | FTM016 (1960 W) |
| BYWT301MA40P11 | 2003 W | 23.9 m³ | FTM022 (2234 W) |
| BYWT302MA50P11 | 2503 W | 31.9 m³ | FTM028 (2526 W) |
| BYWT352MA60P11 | 3085 W | 41.5 m³ | FTM034 (2995 W) |
| BYWT352MA70P11 | 3325 W | 45.6 m³ | FTM040 (3389 W) |
| BYWT352MA80P11 | 3877 W | 55.0 m³ | FTM040 (3389 W), one size up |
BEST Easy Freezer Range
| Model | Capacity | Room size | Replaces old FA/FT |
|---|---|---|---|
| BYWT251LA10P11 | 694 W | 4.9 m³ | FTL003 (671 W), FTL006 (817 W) |
| BYWT251LA20P11 | 925 W | 7.5 m³ | FTL009 (953 W) |
| BYWT301LA30P11 | 1065 W | 9.1 m³ | FTL012 (1266 W) |
| BYWT301LA40P11 | 1177 W | 10.4 m³ | FTL012 (1266 W), one size up |
| BYWT302LA50P11 | 1579 W | 18.2 m³ | FTL016 (1577 W) |
| BYWT352LA60P11 | 2165 W | 29.6 m³ | FTL020 (1914 W), FTL024 (2343 W) |
| BYWT352LA70P11 | 2392 W | 34.4 m³ | FTL034 (2547 W) |
Capacities and room sizes are Rivacold's ratings. Old FA/FT units are the R452A versions. Data sheets for each model are in the Data Sheets section above. Some BEST Easy units have less capacity than the unit they replace, even where they're rated for a bigger room, for example the BYWT301MA30P11 (1645 W) against the old FTM016 (1960 W). Read Getting the Size Right below before deciding whether to go up a size.
Getting the Size Right
Size the unit to the room's actual load, not just its volume, and not bigger to be on the safe side. Rivacold specifically advise against oversizing, and there are good reasons for it.
- Too small: the unit runs flat out and still can't hold temperature on busy days, when the door's open a lot or warm stock goes in.
- Too big, short cycling: an oversized unit pulls the room down quickly, switches off, then switches back on a few minutes later. Lots of short runs instead of steady ones. Every start is the hardest moment for a compressor, so it wears faster, oil doesn't return to it properly, and the unit costs more to run.
- Too big, room pressure: cold air takes up less space than warm air. A big unit in a small room cools the air so fast it pulls a slight vacuum, which is why some freezer doors are hard to open straight after closing them, and why panels get stressed. Hot gas defrost does the opposite and pushes the room out. Freezer rooms need a pressure relief valve for this reason, and oversizing makes it worse.
- Too big, refrigerant pressure: a big evaporator in a small room runs out of heat to absorb. Suction pressure drops too low, the coil can ice up, and the unit can trip on low pressure or send liquid back to the compressor.
If the old unit struggled, get the room load worked out properly before choosing, taking in door openings, the stock going in and the temperature outside the room. If you're not sure, send us the room size and how it's used and we'll point you in the right direction.
Reading a BEST Easy Model Number
BY W T 301 M A 30 P 11
- BY: BEST Easy (full BEST models start BE)
- W: wall-mounted
- T: through-wall (S is saddle-mount, sitting over the top of the wall)
- 301: unit size (251, 301, 302 or 352)
- M: medium temperature, chiller (L is low temperature, freezer)
- A: air-cooled condenser
- 30: capacity step within that size
- P: R290 propane refrigerant
- 11: 230V single phase
Other Current Rivacold Ranges
To help identify your unit.
- BEST WS/WT: the full-spec version of BEST Easy, wall-mounted (model numbers start BE). Uses the BEST wall unit manual above.
- BEST CM: ceiling-mounted units, replacing the old FS Blocksystem range
- BOLD: wall-mounted units for outdoor installation
- SF: ceiling-mounted units for coldrooms
Older Rivacold Units
Blocksystem units, including the FA and FT ranges that BEST replaced.
Rivacold Blocksystem Controller Handbook
Controller guide for older Rivacold Blocksystem units. Covers start-up, setting the room temperature, changing parameters, alarm codes and emergency running if the controller fails.
Use this for: older Blocksystem units with the four-button controller (SET, UP, DOWN and ON/OFF). If you have an older FT unit, send us the model number and a photo of the controller and we'll confirm it's the right handbook.
Download Handbook (PDF)Can't Find Your Manual?
Send us your unit's model number, serial number and a clear photo of the controller, and we'll help you find the right document. Before changing any settings or working on a unit, make sure the manual matches your model and follow the manufacturer's safety instructions.